5-zone plan based on Eliya's plans (Feb 18) — 250m², Ko Pha Ngan
Based on Eliya's Ceiling & Lighting plan (Feb 18). Current plan: 4x mini-central + 8x high-wall splits. We're consolidating into 3 ducted zones with dampers, 1 wall split, and 1 cassette.
| Room | Current Plan | New Plan | Change |
|---|---|---|---|
| Main Living + Kitchen | Mini-central | Ducted | No change ✓ |
| Master bedroom | High-wall split | Ducted Damper | → Zone 2 |
| Kids bedrooms (x3) | 3x High-wall split | Ducted 3x Damper | → Zone 2 |
| Airbnb living | Mini-central | Ducted | → Zone 3 (merged) |
| Airbnb bedrooms (x2) | 2x High-wall split | Ducted 2x Damper | → Zone 3 (merged) |
| Guest cabin | AC (unspecified) | Wall Split | Defined (vaulted) |
| Office | AC (unspecified) | Cassette | Defined ✓ |
Thai market prices, inverter models. Includes unit + standard installation. Ductwork, dampers, insulation, and diffusers additional.
| Zone | Type | Indoor | Outdoor | Est. Cost |
|---|---|---|---|---|
| 1. Main Living | Ducted | 1 | 1 | 100K–150K ฿ |
| 2. Bedrooms (x4) | Ducted 4x D | 1 + 4 dampers | 1 | 120K–180K ฿ |
| 3. Airbnb (full) | Ducted 2x D | 1 + 2 dampers | 1 | 100K–160K ฿ |
| 4. Guest Cabin | Wall Split | 1 | 1 | 20K–30K ฿ |
| 5. Office | Cassette | 1 | 1 | 35K–55K ฿ |
| TOTAL ESTIMATED | 5 outdoor | 375K–575K ฿ | ||
| ~40,000–61,000 ILS | ~$11,000–17,000 USD | ||||
5 indoor units + 6 dampers + 5 outdoor units. Down from 12 indoor + 7+ outdoor in original plan.
Gold Fin / Blue Fin coated outdoor units required. Stainless steel or PVC dampers only. Rinse outdoor units monthly. Position leeward.
PRIMARY RISK. All ductwork: closed-cell elastomeric foam insulation + vapor barrier. NOT fiberglass. Any gap = mold. Annual duct inspection.
250m² with 5 AC zones likely needs 3-phase (380V). Confirm with PEA. Already in Carlos's scope.
Ducted units on structural steel in roof void. Maintained via roof hatch — no ceiling access panels. Plywood catwalks along maintenance paths. Optional slim filter slots only.
Ducted: Daikin WiFi adapter → Home Assistant. Cassette/wall: Tuya ZS06 Zigbee IR blaster (~600฿). Dampers: zone controller with Modbus/IoT.
FC board at 3.00m, roof peak ~6m = 3m void. Ample for units + ductwork. Steel frames hung from trusses (Yuki to spec). Guest cabin: vaulted = no void → wall split.
Ask Carlos and Yuki if they have HVAC contacts with ducted + zone damper experience. Key questions: Have you installed motorized zone dampers? Can you service on KPG? What duct insulation do you use? If no suitable contractor can be found, we drop the dampers and revert to the current plan — wall splits for bedrooms, ducted only for living areas.